Comment calculer la puissance sur un élément chauffant en MoSi2 en forme de U ?

2023-02-24 00:10 3,979
notation :

To compute the power in watts on the mosi2 heating element the length of the hot zone, the surface area of the hot zone, and the watt loading in watts per square centimeter (W/cm²) must be determined.

The heating length of a “U” shaped element consists of 2 legs and a 180º bend. Use the formula below to calculate the overall heating length.

Élément chauffant en Mosi2 en forme de U
Élément chauffant en Mosi2 en forme de U

Étape 1

To obtain the total length of the hot zone in mm, add the bend allowance (z) from the table below to twice the straight heated length (Le).

LH = 2(Le) + z

Étape 1 : La sécurité d'abord !

Hot-zone diameter (mm)Leg spacing, a (mm)Bend allowance, z (mm)Area per length, c (mm²/mm)
3208.409.42
32511.259.42
4207.4012.56
42510.2512.56
64016.8018.84
65022.5018.84
66028.2018.84
95019.5028.26
96025.2028.26
126022.2037.68
Use the row that matches the element diameter and leg center spacing.

Multiply the hot-zone length (LH, in mm) by c from the same row to get the surface area in mm².

Divide that area by 100 to get cm². Multiply by the selected surface load (W/cm²) to get power in watts. The Kanthal Super handbook shows surface load by furnace temperature for its element grades.